Quick answer
A generator GFCI outlet that is not working has usually tripped because it senses current leaking to ground, often from a damp cord, a worn tool or moisture inside the panel. Press the reset button with everything unplugged and the engine running. If it will not reset or will not stay reset, the outlet may be worn out, or there may be a wiring or moisture problem inside the generator.
What a GFCI does
A ground-fault circuit interrupter compares the current going out through the hot conductor with the current coming back. If a small amount goes missing, which could mean it is flowing through a person or through water, it cuts power fast. Generators that have GFCI outlets use them for protection, especially outdoors and in damp locations.
It won’t reset
- Unplug everything from the generator.
- With the engine running, press the TEST button, then press RESET firmly. Some outlets will not reset unless the generator is running and supplying power.
- Try again after drying the panel and the outlet. Moisture is a very common reason.
- Check the main breaker and the breaker for that outlet.
If it still will not reset with nothing connected, the GFCI itself may be worn out, or there may be a ground fault or moisture in the wiring behind it. Replace the GFCI with an equivalent part, or have a technician look at the internal wiring.
It keeps tripping
If it trips only after you plug something in, the issue is probably with that cord or device:
- Test the item on another GFCI-protected outlet, if safe, to see whether it trips there too.
- Inspect cords for cuts, damaged insulation or exposed conductors.
- Wet or damp tools, trimmers and pressure washers can leak enough to trip it.
- Heating elements and old motors can have a small leak to ground.
Some devices with long cable runs or certain electronic loads can also cause nuisance tripping. A different cord or a different outlet may help.
The GFCI is dead but the generator works
If the engine runs, the other outlets work, and only the GFCI outlet is dead, that outlet has likely failed or has lost its supply. Check the breaker that feeds it. Many portable generators have a separate breaker for each outlet type. If the breaker is fine, the GFCI unit or a loose connection is the likely cause. A generator with no output at all is a different problem; see generator running but no power.
A note about grounding and bonding
How the neutral is connected to the frame differs from one portable generator to another, and some designs have a floating neutral. This affects whether GFCI protection works as expected when using the generator with extension cords or with a transfer switch. Check your manual before making any changes to grounding, and do not modify the wiring yourself. For connecting to a house, see generator transfer switch explained.
Safety
Never bypass or tape over a GFCI. Keep the generator under a proper cover that allows ventilation, run it outside, and keep cords out of puddles. If the breaker trips as well, see generator breaker keeps tripping.