Short answer
A transfer switch is a device that safely connects a generator to your home’s wiring and disconnects the house from the utility grid while the generator is running. It lets you power selected circuits, like a furnace blower, refrigerator or lights, without running extension cords all over the house. It also prevents backfeeding, which is a serious danger to utility workers and your equipment.
Transfer switches involve your home’s electrical system and local codes. This article is general background, not installation instructions. Have a licensed electrician do the work.
Why you need one
Plugging a generator into a household outlet with a homemade “double-male” cord is dangerous and illegal in many places. Power can flow backward through the service connection to the utility transformer and energize lines that crews believe are dead. It can also damage the generator and house wiring when utility power comes back. A transfer switch (or an approved interlock) physically prevents the house from being connected to both sources at once.
Common types
- Manual transfer switch. A separate small panel, wired to a set of chosen circuits. When the power is out, you start the generator, connect it with a cord and flip the switch from utility to generator.
- Interlock kit. A mechanical device added to your main panel that blocks the main breaker and generator breaker from being on at the same time. Whether it is allowed depends on your panel and local codes, and it must be one approved for your specific panel.
- Automatic transfer switch. Used with permanently installed standby generators. It detects an outage, starts the generator and switches over without help. This is a different category from most portable generators.
The inlet and the cord
Portable generator systems typically use a power inlet box mounted on the outside of the house, wired to the transfer switch or panel. A heavy-duty cord with matching connectors links the generator to the inlet. The generator and inlet need to match in amperage and plug type. Check the generator’s output receptacle and your manual.
Sizing
Your transfer switch needs to match the generator’s output. Choose circuits whose combined load stays within what the generator can supply. Large loads like electric ranges, central air conditioners or electric water heaters may be too much for a small portable unit. For a rough method, see how to calculate generator wattage needs. If you push the unit too hard, you may notice generator overload symptoms.
Installation
- Hire a licensed electrician.
- Ask whether a permit and inspection are required in your area. In many places they are.
- Ask about the inlet location. It should be outside, and the generator should sit where its exhaust cannot reach the house. See how far from house to run generator.
- Ask the electrician to label the circuits and show you how to operate it.
Using it
The general order is: turn off or unplug the loads, start the generator outdoors, let it stabilize, switch the transfer switch to generator and add loads one by one. When utility power returns, switch back, then shut down the generator. Always follow the instructions from the switch’s manufacturer and your electrician.
If the generator runs but there is no output, see generator running but no power. Keep the generator itself in good shape with the steps in generator maintenance schedule.