Generator Power Problems

How to Test a Generator Capacitor

Learn how to test a generator capacitor safely: discharge it, inspect it, then measure capacitance with a multimeter and compare the reading with the rating.

On this page
  1. Quick answer
  2. What the capacitor does
  3. Safety first
  4. Visual inspection
  5. Testing with a capacitance meter
  6. Testing with a basic ohmmeter
  7. Replacing it

Quick answer

To test a generator capacitor, shut the generator down, let it stand, and discharge the capacitor safely. Disconnect it, then measure its capacitance with a meter that has a capacitance (µF) setting and compare the result with the rating printed on the label. A reading well below the rating, or no reading at all, means the capacitor is weak or failed. Visible bulging, leaking or burn marks mean it should be replaced no matter what the meter says.

What the capacitor does

On many brushless portable generators, a capacitor in the excitation circuit helps the alternator build and hold its output voltage. When it weakens or fails, typical symptoms include:

  • A running engine with very low or no output (see generator running but no power)
  • Voltage that is low or sags under load (see generator low voltage output)
  • Output that is fine with no load and collapses when you plug something in
  • Output that comes and goes

Not every generator has this kind of capacitor, and brushed models may have different parts, so check your manual or the parts diagram.

Safety first

A capacitor can hold a charge after the engine stops. Before touching it:

  1. Shut the engine off and disconnect the spark plug wire so it cannot start.
  2. Unplug everything from the outlets.
  3. Wait, then discharge the capacitor. A common method is to bridge its terminals with a resistor of a few thousand ohms and sufficient power rating, using insulated tools, for a few seconds. Do not short the terminals with a screwdriver: that can cause a spark or damage the capacitor.
  4. Wear eye protection and avoid touching the terminals with bare hands.

If you are not sure how to do this, have a technician test the capacitor.

Visual inspection

Look for a bulged top or bottom, oil or residue leaking, cracked casing, burnt wires or melted insulation. Any of these is enough to condemn it. Check the connectors as well: corroded or loose terminals can imitate a bad capacitor.

Testing with a capacitance meter

  1. Note the rating on the label, usually given in microfarads (µF) with a tolerance, for example ±5% or ±10%.
  2. Disconnect the leads, noting where each goes. A quick photo helps.
  3. Set a multimeter with a capacitance function to the µF range.
  4. Touch the probes to the terminals. Some meters take a few seconds to settle.
  5. Compare. A reading close to the rating and within tolerance is good. A reading well below the rating or a reading of zero indicates a bad capacitor.

Capacitors with more than two terminals or with separate sections need to be checked per the label or the service manual.

Testing with a basic ohmmeter

If your meter has no capacitance mode, a resistance test is much less reliable. A healthy capacitor shows a low resistance that rises as it charges. A capacitor that shows continuity (a steady near-zero reading) is shorted, and one that never moves is open. This will not tell you whether the capacitance is in range, so a capacitance meter is preferred.

Replacing it

Replace a bad capacitor with one that matches the µF rating and voltage rating, ideally the manufacturer’s part number. Using the wrong value can reduce output or overheat the windings. After replacing it, check output with a multimeter. If voltage is still absent, review how to flash a generator field and the other causes in generator running but no power.

The complete guide to generator power problems