Quick answer
Low voltage from a portable generator is most often caused by the engine running too slowly, the generator being overloaded, or a weak or failed capacitor. Very low readings, for example a small fraction of the rated voltage, often mean the generator has lost the magnetism it needs to build up output, or a regulator or winding is faulty.
What counts as low
Most North American portable generators are rated for 120V, 240V or both, and a reading a little off the nominal value is normal. Many are designed so that voltage and frequency are somewhat higher with no load and settle as the load goes up. Your manual may list the expected range. If you have no figures, large deviations, readings that sag a lot as soon as you add a load, or readings far below the nominal value are what you should chase.
Measure both with the generator unloaded and with a moderate load, using a multimeter set to AC volts. Take care: you are working near live contacts.
Engine speed
Voltage on a conventional generator follows engine speed. If the engine is running slowly because of stale fuel, a dirty carburetor, a dirty air filter, or a governor problem, voltage drops along with frequency. The article on generator RPM and frequency explains how speed and output are linked. If the engine sounds rough or you see surging, fix that first; how to clean a generator carburetor is a common starting point.
Overload
An engine pulled down by too much load will lose speed and voltage together. Signs include a laboring sound, a drop in speed when a device starts, and a tripping breaker. If this sounds familiar, review generator overload symptoms and learn how to calculate generator wattage needs to see whether the combined load is too high.
Cords and connections
Long, thin or damaged extension cords drop voltage between the generator and the equipment, so the reading at the tool may be lower than at the generator. Use a heavy cord, keep runs as short as practical, and avoid daisy-chaining. Check that the plug and outlet fit tightly and do not feel hot.
Capacitor, residual magnetism, regulator and brushes
If the engine runs well but output is low even without a load, the problem is probably in the electrical side:
- A weak capacitor can reduce output. See how to test a generator capacitor.
- Lost residual magnetism can leave output very low; some generators can be restored by flashing the field. See how to flash a generator.
- A failing automatic voltage regulator or worn brushes can cause low or unstable output on models that use them.
- Winding faults in the stator or rotor can reduce voltage, and these often show up as output that drops sharply when a load is added.
Without service information for your exact model, it is hard to say which of these applies, so a technician may be needed.
Why low voltage matters
Running motors or electronics on low voltage can cause overheating and damage. If your generator produces clearly low voltage, avoid connecting sensitive equipment such as computers, medical devices or modern appliances until you have repaired it. For a generator that runs but delivers nothing, see generator running but no power.