Flashing the field restores lost residual magnetism in some generators. Learn when it applies, what to rule out first, and the cautions before you try it.

On this page
  1. Quick answer
  2. Signs of lost residual magnetism
  3. Rule out other causes first
  4. The general idea
  5. What not to do
  6. If it doesn’t work

Quick answer

“Flashing the field” means briefly applying a small DC current to a generator’s field to restore the weak residual magnetism that lets the machine build up its own voltage. It applies mainly to older or brush-type designs, and the exact method depends on the model. Many modern portable generators use a capacitor-based design where the first suspect for low output is the capacitor, not the field. Because the wrong connection can damage the generator, check your manual or ask the manufacturer for the procedure for your specific model.

Signs of lost residual magnetism

  • The engine runs normally and sounds healthy.
  • The outlets show little or no voltage, perhaps just a few volts.
  • The generator has sat unused for a long time, was run with a dead short or was knocked hard.
  • Breakers and outlets check out fine.

These signs overlap with several other faults, so do not assume it is the field. See generator running but no power for the full list.

Rule out other causes first

  1. Check all breakers and GFCI outlets.
  2. Confirm the engine is running at proper speed. Low speed gives low voltage (see generator low voltage output and generator RPM and frequency).
  3. Test the capacitor if your generator has one. See how to test a generator capacitor.
  4. Look for worn brushes or loose connections if the model has them.
  5. Disconnect all loads. A short or a faulty appliance can pull output down.

The general idea

The method differs between designs, so treat the following as an overview, not a how-to:

  • On many brush-type generators, a technician briefly applies a low-voltage DC source, such as a battery, to the field circuit while the engine runs or sits stopped, following the polarity and terminals shown in the service documentation.
  • On some designs, running the generator with a light load can help rebuild the magnetism.
  • On others, the manufacturer’s procedure uses specific points on the capacitor or the field winding.

Polarity matters because reversing it can cancel the magnetism rather than restore it. Wiring to the wrong points can damage the regulator, diodes or windings. Never connect a source to the AC output outlets. Do not try this on inverter generators; their electronics can be damaged easily.

If you proceed, work with the engine stopped unless the documentation says otherwise, wear eye protection, keep the contact brief, and keep your hands away from moving parts, the muffler and any live terminals.

What not to do

  • Do not guess at wire locations.
  • Do not apply mains power or a high-voltage source.
  • Do not leave a battery connected to the field for long.
  • Do not repeat the process many times: if it keeps losing its magnetism or never holds, something else is wrong.

If it doesn’t work

If output does not return, or it returns and disappears again, the likely suspects are a failed capacitor, an open winding, a bad regulator or worn brushes. A technician with the service manual can test resistance values and diodes to find which. For a generator that also trips breakers or surges, consider whether those symptoms might share a cause and see generator breaker keeps tripping and generator surging.