Generator Power Problems

Generator Running but No Power Output

Generator running but no power at the outlets? Work through breakers, GFCI, engine speed, voltage tests, the capacitor and field before assuming the worst.

On this page
  1. Quick answer
  2. Start with the easy checks
  3. Check engine speed
  4. Check output voltage
  5. Lost residual magnetism and a failed capacitor
  6. Other electrical causes
  7. Safety notes
  8. When to call a technician

Quick answer

When a portable generator runs normally but nothing works when you plug it in, the cause is usually one of a few things: a tripped breaker or GFCI, a bad cord or outlet, an engine running too slowly, or a problem in the part of the generator that creates the electricity (the capacitor, the field, the brushes, the voltage regulator or the windings). Work from the simple items to the complicated ones. Many people fix this with a reset button or a cord swap and never open the generator.

Start with the easy checks

  1. Check the breakers. Most portable generators have one or more breakers on the control panel. Push each one fully to off, then back on. A breaker that looks “on” can still be tripped.
  2. Check any GFCI outlet. Press the reset button on the generator’s GFCI outlet. If it will not stay reset, see the article on generator GFCI not working.
  3. Try a different outlet and a different cord. A damaged extension cord is a surprisingly common cause. Use a heavy-duty cord rated for the load.
  4. Try a known-good load. Plug in a work light or a small tool you know works. A dead appliance can look exactly like a dead generator.
  5. Unplug everything and start again. If a connected device is faulty, it can trip the protection each time. Start the engine with nothing plugged in, let it settle, then add loads one at a time.

If your generator has an “outlet selector” or a switch for 120V and 240V, confirm it is on the setting that matches the outlet you are using. Some models also have an eco or economy switch that changes how the engine responds to load.

Check engine speed

A generator that runs but sounds sluggish may not be turning fast enough to make full voltage. Most conventional portable generators run at a fixed speed so the output stays near 60 Hz in North America (see generator RPM 3600 Hz frequency for the reasoning). If the engine is hunting, loping or running rough, the output can drop or collapse. Common causes are stale fuel, a dirty carburetor, a stuck choke or a governor problem. A generator surging is a related symptom that deserves its own look.

If the engine runs poorly, fix that first. A dirty fuel system is the most frequent culprit, and many owners need to learn how to clean a generator carburetor.

Check output voltage

If you own a basic multimeter, you can measure what the outlet is delivering. Set it to AC volts, then carefully insert the probes into the slots of a 120V outlet with the engine running. Only do this if you are comfortable working near live electricity, and keep your hands on the insulated parts of the probes.

  • Close to the rated voltage (around 120V): the generator is probably fine and the fault is downstream: a cord, a breaker in the circuit, or the appliance.
  • Very low voltage, for example a few volts to a few tens of volts: this suggests the generator is not building up its magnetic field. The capacitor or field are the usual suspects.
  • Zero: check the main breaker, the outlet wiring and any inline fuse or reset before suspecting the windings.

Compare readings with and without a load, because a damaged component may show enough voltage at idle yet collapse as soon as you plug something in.

Lost residual magnetism and a failed capacitor

Many portable generators rely on a small amount of leftover magnetism in the rotor to start producing electricity. If the machine sat for a long time, was shocked by a hard jolt, or has been run with a short circuit, that magnetism can fade, and the generator may run but produce very little voltage. The usual remedy is to re-magnetize the field, a process known as “flashing”. The details differ by design and getting it wrong can damage the unit, so read how to flash a generator field and check your manual first.

On many brushless generators, a capacitor helps create the excitation that the output depends on. A weak or failed capacitor can leave you with low or no voltage. Testing is straightforward with a capacitance meter, covered in how to test a generator capacitor.

Other electrical causes

  • Worn brushes or dirty slip rings on brush-type models can interrupt the field current.
  • A failed automatic voltage regulator (AVR) on models that have one can prevent output.
  • Open or shorted windings in the stator or rotor. These can often be checked with a multimeter by comparing resistance to the values in the service manual, but you will need that manual.
  • A damaged main breaker or internal wiring, including loose or burnt connections after an overload.
  • Inverter generators work differently: a controller and inverter board make the output. A fault code, warning light or overload indicator is usually the first clue, and these units generally call for the manufacturer’s service information.

Safety notes

Generators produce potentially dangerous voltage, and the engine produces carbon monoxide. Run the unit outdoors only and well away from windows, doors and vents. Never connect a generator to your home wiring by plugging it into a wall outlet; use a properly installed transfer switch (see generator transfer switch explained). Shut the engine off and let it cool before opening any panel.

When to call a technician

If you have verified the breakers, the cord, the engine speed and the capacitor and still have nothing, internal winding or regulator faults usually need a technician or a service manual with exact test values. For a generator that is under warranty, contact the manufacturer before opening it.