Quick answer
When a generator won’t start after sitting, the usual cause is old fuel that has left varnish or gum in the carburetor. Replace the fuel first, then clean the carburetor if it still won’t run. Also check the oil, spark plug, air filter and battery, and look for pests that moved in.
Safety
Work outdoors, with the engine cool and nothing connected. Keep fuel in approved containers away from sparks and flames, and dispose of old gasoline according to your local rules; many areas have drop-off sites.
Why stored generators fail to start
Gasoline slowly degrades, and ethanol blends can absorb moisture. After a few months, the fuel may leave sticky deposits that block the tiny passages in a carburetor. Rubber parts can dry out, batteries self-discharge, and mice sometimes nest in air boxes and mufflers. Fuel that sat for a long time is the first thing to suspect. If you want the broader picture of ethanol, see does ethanol gas damage small engines.
Step-by-step restart
1. Inspect the generator
Look around the engine for nests, chewed wires and debris in the air intake and muffler. Check the air filter housing. Remove anything that doesn’t belong.
2. Check and top off the oil
Confirm the oil level and look at its condition. If it’s milky, very dark, or the unit has been run a long time since the last change, change it. See how to change oil in a portable generator. Low oil can also keep the engine from starting; see generator low oil shutdown won’t start.
3. Drain the old fuel
Close the fuel valve if there is one, then drain the tank and carburetor bowl into an approved container. Fill with fresh gasoline. If you’re unsure whether the fuel is bad, replacing it is cheap compared with repeated starting attempts.
4. Check the spark plug
Remove it and inspect. Replace it if it is wet with fuel, fouled with deposits, or worn. See how to change spark plug on portable generator.
5. Try to start
Use the choke as the manual describes (generator choke position explains typical settings) and attempt a start. If the engine fires and dies, or runs only on choke, the carburetor is probably partly blocked.
6. Clean the carburetor
If fresh fuel doesn’t solve it, the carburetor likely needs cleaning. See how to clean generator carburetor. Running cleaner through the intake rarely reaches the small jets, so removing the bowl and cleaning the main jet is usually more effective.
7. Check the battery
For electric start models, a battery that sat all season may be flat. Charge it or replace it. See generator electric start not working.
If it still won’t start
Go through the broader portable generator won’t start troubleshooting list, especially if it turns over but won’t start. If the engine is hard to turn or pull, don’t force it; see generator pull cord stuck.
Preventing a repeat
- Before storage, either use a fuel stabilizer, following the product’s directions (see how much fuel stabilizer per gallon), or drain the fuel system.
- Store it clean and dry, covered, and away from rodents.
- Run it periodically; see should you run generator monthly.
- For detailed steps, see how to store a generator long term.