Quick answer
If the electric start on your generator does nothing, clicks, or turns the engine slowly, the most likely cause is a weak or discharged battery, or a poor connection at the battery terminals. Next most likely are a safety interlock (such as low oil or the switch position) and a failed starter solenoid or motor.
Safety first
- Work outdoors and keep the area ventilated; never run a generator indoors or in a garage.
- A battery can produce enough current to cause burns or sparks if a tool bridges the terminals. Remove jewelry and be careful with metal tools.
- Keep open flames and sparks away from the battery and fuel.
- If the battery is swollen, cracked or leaking, don’t try to use it. Replace it.
Identify the symptom
- Complete silence, no lights or sound: battery fully dead, disconnected, fuse blown, or the key or switch not powering the circuit.
- Rapid clicking: the battery has too little charge to turn the starter, or terminals are corroded or loose.
- Single loud click: possibly a bad solenoid or starter motor.
- Slow cranking: weak battery, bad connections, or an engine that’s hard to turn.
1. Check the battery
Look at the terminals for white or green corrosion and check that cables are tight. If you have a multimeter, a fully charged 12-volt battery typically reads in the area of 12.6 volts at rest; much lower readings suggest it needs charging or replacement. If you can, charge it with a charger suitable for that battery type, following the charger’s instructions. A battery that won’t hold a charge is worn out.
2. Clean and tighten connections
Disconnect the negative cable first, then the positive. Clean terminals and cable ends with a wire brush, and reconnect the positive cable first, then the negative. Check the ground wire to the engine frame too, since a loose ground can mimic a dead battery.
3. Check the switches and interlocks
- The start switch should be in the correct position, usually run or start, not off.
- Many units won’t crank if the oil level is low. See generator low oil shutdown won’t start.
- Some have an emergency stop or a breaker on the control panel that has to be reset.
- Check any fuse in the starter circuit; the manual shows where it is.
4. Starter solenoid and motor
If the battery is good and the connections are clean, but you hear only a click, the solenoid or starter motor may have failed. Testing these usually needs a multimeter and some wiring knowledge. If you’re not confident, a repair shop can do it quickly.
5. Use the backup
Many electric-start generators also have a pull cord. If the engine is otherwise healthy, you can use it to get going while you sort out the battery. If the pull cord is also stuck, see generator pull cord stuck. If the engine turns over but won’t fire, see generator turns over but won’t start.
Keep the battery healthy
Batteries on infrequently used generators often go flat. A maintenance charger helps, and some units charge the battery while running. Disconnecting the battery during long storage can also help; see how to store a generator long term and should you run generator monthly.
When to get help