  1. Quick answer
  2. What the choke does
  3. Reading the lever
  4. Cold start steps
  5. Warm or hot start
  6. Problems that look like choke trouble
  7. Quick tips

Quick answer

For a cold start, the choke is usually set to closed (fully or mostly on). Once the engine runs and warms up, you gradually open it to the run position. For a warm engine, the choke is normally left open or only partly closed. Because the lever style and direction vary by model, check the markings on your generator and the owner’s manual.

What the choke does

The choke restricts the air going into the carburetor so the mixture is richer, with more fuel relative to air. A cold engine needs this to start. Once warm, the same rich mixture causes rough running, smoke and wasted fuel, which is why you open the choke as the engine warms.

Reading the lever

Most portable generators use one of these:

  • A lever or slider marked with a choke symbol (a small circle with a bar) and a run position. Often “choke” is toward the closed side and “run” toward the open side, but this differs between models.
  • A knob you pull out for choke and push in for run.
  • A rotary dial or tab on the carburetor or air box.
  • Automatic choke with no manual control. The engine manages the mixture on its own.

If your control isn’t labeled, look at the carburetor: closed means a plate blocks most of the air opening.

Cold start steps

  1. Check oil and fuel, and open the fuel valve.
  2. Set the choke to the choke or start position.
  3. Turn the engine switch on, and use the primer if your model has one.
  4. Pull the cord or press the start button. See how to start a portable generator for the full sequence.
  5. When the engine fires, let it run for a few seconds, then move the choke partway open.
  6. Open the choke fully to run as the engine smooths out, usually within a minute or so.

Warm or hot start

If the engine was running recently, start with the choke open or only slightly closed. Too much choke on a hot engine can flood it. If it floods, see generator turns over but won’t start for checks, and let it sit a few minutes with the choke open while you pull a few times.

Problems that look like choke trouble

  • Only runs with the choke on: this suggests a lean condition, often from a dirty carburetor. See how to clean generator carburetor.
  • Dies when you open the choke: you may be opening it too soon, or the carburetor is partly blocked. See generator starts then dies.
  • Smoky, rough or sooty running: the choke might be stuck partly closed, or the air filter may be dirty.
  • Hard to start even with correct choke: check fuel, spark and the rest of the portable generator won’t start troubleshooting list.

Quick tips

  • Don’t leave the choke closed during normal running.
  • If the lever doesn’t move or doesn’t seem to change anything, look at the linkage at the carburetor.
  • Always follow your owner’s manual if it differs from this general description.