Generator Won’t Start

Generator Starts Then Dies

A generator that starts and then dies usually has a fuel delivery problem, a dirty carburetor or a low-oil shutdown. Here are the checks to run, in order.

On this page
  1. Quick answer
  2. Safety note
  3. Note when it dies
  4. 1. Check the oil
  5. 2. Open the fuel cap vent
  6. 3. Check the fuel
  7. 4. Clean the carburetor
  8. 5. Look at the choke
  9. 6. Air filter and spark plug
  10. 7. Overload or load-related shutoff
  11. When to get help

Quick answer

A generator that starts and then dies is usually getting some fuel, but not enough to keep running. The most common reasons are a partly clogged carburetor, a closed fuel cap vent, or a low-oil shutdown. Because it does start, ignition is probably working, which narrows things down.

Safety note

Run the generator outdoors, away from windows and doors, and with nothing plugged in while troubleshooting. Let the engine cool before touching fuel parts, and keep spills cleaned up.

Note when it dies

The timing is a clue.

  • Dies within a few seconds: often a low-oil sensor, or a carburetor that passes enough fuel to start but not to idle.
  • Runs only with choke partly on: points toward a lean condition from a dirty carburetor or air leak.
  • Runs a few minutes and quits: may be a fuel vent problem, fuel starvation, or the engine overheating or an overload shutdown.
  • Dies when you add a load: see below.

1. Check the oil

Make sure the generator is on level ground and the oil is at the full mark. Low-oil systems typically shut the engine off almost immediately. If the oil is full and it still stops, the sensor may be faulty. The page on generator low oil shutdown won’t start has more.

2. Open the fuel cap vent

Many generator fuel caps have a vent that must be open (on some models it’s a small lever or screw). If it’s closed, a vacuum builds in the tank and fuel stops flowing after a short time. Open it and try again.

3. Check the fuel

Old fuel is a frequent cause. If the generator has sat for months, drain the tank and refill with fresh gas. If you stored it for a long time, see generator won’t start after sitting. Check that the fuel valve is fully open too, and that the screen or filter isn’t blocked.

4. Clean the carburetor

When fuel passages are partly blocked with varnish, the engine may fire on the fuel in the bowl and then starve. Cleaning the carburetor is often the fix. See how to clean generator carburetor. On some carburetors a small bowl nut or jet is the culprit, and spraying carburetor cleaner on the outside won’t reach it.

5. Look at the choke

If the engine only keeps running with the choke on, it’s probably running lean. That points to a dirty carburetor or an air leak. If it dies when you move the choke off too soon, try again with the choke on a little longer on a cold engine. See generator choke position for typical settings.

6. Air filter and spark plug

A clogged air filter or worn spark plug can make an engine unstable. Clean or replace them if they look dirty. See how to clean generator air filter and how to change spark plug on portable generator.

If it runs fine until you plug something in, the generator may be overloaded, or the load may have a large starting surge. Disconnect everything, start it, let it settle, and then add loads one at a time. See generator overload symptoms and generator surging if the engine speed hunts up and down.

When to get help

If none of this works, the problem could be internal, such as a fuel pump (on larger models), valve issues or an ignition fault that only shows when hot. A shop can diagnose these quickly. For the wider checklist see portable generator won’t start troubleshooting.

The complete guide to generator won’t start