Short answer
To change the oil in a portable generator, run it briefly to warm the oil, shut it off and let it cool a little, drain the old oil into a pan, put the drain plug back, refill with the oil your manual specifies, and check the level on the dipstick. The whole job usually takes 15 to 30 minutes.
How often depends on the model. Many manuals call for a change every season or after a set number of running hours, and an earlier change when the engine is new. Check yours.
What you need
- The oil type and quantity listed in your owner’s manual
- A drain pan or a container sized for the crankcase
- A wrench or socket for the drain plug, if your model has one
- A funnel
- Rags or paper towels
- Gloves and eye protection
- A sealable container for the used oil
Step by step
- Warm the engine. Run the generator with no load for a few minutes. Warm oil drains more completely and carries more contaminants out with it.
- Shut it off and make it safe. Turn it off, let it cool until you can touch the engine, and disconnect the spark plug wire so it cannot start by accident. The engine can stay hot enough to burn you, particularly around the muffler.
- Set up on level ground. Position the generator so the drain point is accessible and the pan will catch the flow.
- Remove the fill cap or dipstick. This lets air in so the oil drains smoothly.
- Drain the oil. Many units have a drain plug on the side or bottom of the crankcase. Remove it and let the oil run out. If there is no drain plug, your manual may tell you to tip the generator and drain through the fill opening. Follow it, and only tip a unit after the fuel situation is dealt with as the manual advises, since fuel can leak from the tank or carburetor.
- Replace the drain plug. Check the washer or seal and tighten snugly. Do not overtighten, since the threads are in soft metal.
- Refill slowly. Add oil through the fill opening in stages, pausing to let it settle.
- Check the level. Follow your manual for whether to screw the dipstick in or just rest it on the opening. The level should reach the mark but not exceed it. Overfilling can cause smoking, a rough run or leaks, which is discussed in what happens if you overfill oil in lawn mower, and the same logic applies here.
- Wipe up and reconnect. Clean any spilled oil off the engine, reinstall the cap, reconnect the spark plug wire, and run the generator briefly. Look for leaks around the drain plug.
Which oil to use
Use the grade and viscosity listed in the manual for your temperature range. Many air-cooled generator engines call for something like SAE 30 or 10W-30, but this varies, so don’t guess. For more background, see what oil for small engine. Some generators also have a low-oil sensor, so topping up to the proper level matters. A low level can keep the unit from starting, which is covered under generator low oil shutdown won’t start.
Disposing of used oil
Do not pour used oil on the ground or into a drain or the trash. Pour it into a sealed container and take it to a recycling location. Many auto parts stores and municipal drop-off sites accept used oil, but policies vary, so call ahead.
Common mistakes
- Skipping the level check after refilling
- Using the wrong oil because it was already on the shelf
- Overfilling
- Losing the drain plug washer
- Forgetting to reconnect the spark plug wire before trying to start it
Oil changes are the single most useful routine task. They fit into the larger plan in the generator maintenance schedule. If your unit is new, also read generator break in oil change.